Features:
1. ECS potestate instructus ratio (Siemens PLC imperium libitum est)
2. Reactivation calefactio (electrica / vapor)
3. Standard power copia est 380V/3phase/50HZ
4. Unitas non includit ventilabrum, superficies frigidiorem et post calefactionem, Quaeso, cum ordinatio
5. Processus aeris volumen range 300m³/h 30000m³/h
VI. Summus vires, humilis ultrices et anti-frigidi pontis aluminium mixturae compago vel frame ferro
7. Latin components: rotor, reactivatio ventilabrum, reactivatio calefacientis
8. Temperature regitur ab AHU a elit
Uvor imperium;
10~40% RH
ZC SERIES DESICCANT DEHUMIDIFIER | |||||||||||||
Exemplar | ZC-D/Z -2000 | ZC-D/Z -3000 | ZC-D/Z -4000 | ZC-D/Z -5000 | ZC-D/Z -6000 | ZC-D/Z -8000 | ZC-D/Z -1000 | ZC-D/Z -12000 | ZC-D/Z -15000 | ZC-D/Z -0000 | ZC-D/Z -25000 | ||
Processus Airflow | m 3 /h | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 | |
Regeneratio Airflow | m 3 /h | 667 | 1000 | 1330 | 1670 | 2000 | 2670 | 3330 | 4000 | 5000 | 6670 | 8350 | |
Ratum Dehumidificationis Capacitas (27 60% RH) | kg/h** | 15.8 | 23.8 | 31.6 | 39.6 | 47.6 | 63.2 | 80 | 93 | 120 | 160 | 200 | |
Reactivatio Consummatio | vapor 04.mpa | kg/h | 40 | 60 | 80 | 100 | 120 | 160 | 200 | 240 | 300 | 400 | 500 |
(diameter) mm | DN20 | DN20 | DN20 | DN20 | DN20 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | ||
Electric | kw | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 150 | 200 | 250 | |
Rated potestas | vapor Reactivation | kw | 0.84 | 1.2 | 1.2 | 1.6 | 1.6 | 2.3 | 3.1 | 3.2 | 5.7 | 7.7 | 11.2 |
Eledtical Reactivation | kw | 20.87 | 31.2 | 41.2 | 51.6 | 61.6 | 82.3 | 103.1 | 123.2 | 155.7 | 207.7 | 261.2 | |
Dimension | longitudo | mm | 1500 | 1600 | 1600 | 1800 | 1800 | 1950 | 1950 | 2150 | 2150 | 2250 | 2250 |
latitudo | mm | 900 | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | 1600 | 1800 | 2000 | 2200 | |
altitudo | mm | 1660 | 1760 | 1860 | 1980 | 2080 | 2180 | 2280 | 2400 | 2750 | 2950 | 3300 | |
Exitus processus aer | mm | 400×250 | 500×320 | 630×320 | 800*320 | 800×400 | 800*500 | 1000*D | 1000*630 | 1250*630 | 1250*800 | 1600×800 | |
Inlet Reactivationis aer | mm | 400×300 | 550×350 | 550×400 | 550* 450 | 650×450 | 750×500 | 750× 550 | 800×500 | 700×550 | 850×550 | 850×650 | |
Exitus Reactivationis caeli | mm | 160-125 | 208×162 | 208×162 | 233* 183 | 233× 183 | 260×228 | 262×204 | 262×204 | 302×234 | 332×257 | 487×340 | |
Unit Pondus | kg | 350 | 420 | 500 | 600 | 700 | 800 | 900 | 1000 | 1200 | 1500 | 1800 | |
Excessus Pressura | Pa | ≤300 | ≤300 | ≤300 | ≤300 | ≤400 | ≤400 | ≤400 | ≤400 | ≤500 | ≤500 | ≤500 | |
Animadverte: Supra parametri subsunt mutationibus secundum nominationem adnexam unit. |